The Heat pump has a hot water tank within a tank. The inner tank is the hot water supply &
the outer tank is part of the distribution side e.g. the radiator circuit. Often air can gather here, so just like radiators, it sometimes needs to be bled. This should normally be done once or twice
following installation and thereafter once a year.
To do this:
Locate the white nipple. For heat pumps model F1220/F1240 this can be found
on the top of the unit. For the VPA
accumulator tank it is located on top of the tank and on the VVM and Fighter 360 there is a black knob at the base of the
tank located behind the lower panel (Refer to the manual).
Once located, twist until all air has been released.
After doing this, the pressure may have dropped on the
heating gauge. If this has happened please
top it up (see Low Pressure (Heating) Section).
NOTES
If you are stuck in any menu, simply move the off set knob
+2 to -2 and you will always come out of the menu you are in.
All information is in the installation manual or at www.nibe.eu
under the relevant model and download documents.